The MSG_TYPE_ERROR (cloud_type=9) arm previously logged only the payload
byte count, so when Qobuz cloud rejected a session (zombie session,
conflicting device, expired JWT, ...) we had no signal beyond an opaque
"bytes=13" TransportError. That hid the actual cause of the 2s flicker
loop seen after the app sat minimized for 1-2 hours (issue #358).
The qws.proto ErrorMessage (messageTypeId=9) carries:
uint32 msg_id = 1
uint64 msg_date = 2
uint32 code = 3
string descr = 4
Decode it via a local QwsErrorMessage prost struct, log a warn line with
the decoded code+descr, and emit a new TransportEvent::CloudError so
qconnect-app and qconnect_service can react. qconnect_service forwards
it as a "qconnect:cloud_error" diagnostic (level=warning) and logs it.
qconnect-app treats it as a no-op forwarder for now, matching the
existing pattern for other transport-only events. Decode failures fall
back to the previous TransportError path under a distinct stage name so
they are still visible.
Adds a tokio test that builds a real MSG_TYPE_ERROR frame and asserts
the transport emits CloudError (not the legacy TransportError).
Refs #358
cc
The native WS transport reset its reconnect counters as soon as the WS
upgrade succeeded. Qobuz cloud accepts the WS connection well before the
JOIN_SESSION exchange and rejects unhealthy sessions with MSG_TYPE_ERROR
right after, so the counter reset every cycle and the loop hammered the
endpoint at base backoff (~2s) forever (issue #358).
Move the counter reset to the moment the cloud emits a
MESSAGE_TYPE_SRVR_CTRL_SESSION_STATE event (the actual proof of a healthy
session-level join), and add a configurable maximum-attempts cap that
makes the transport stop and emit MaxReconnectAttemptsExceeded instead
of looping indefinitely.
- Add SessionEstablished and MaxReconnectAttemptsExceeded transport events.
- Add reconnect_max_attempts to WsTransportConfig (default Some(10)).
- handle_incoming_binary now returns whether SESSION_STATE was decoded.
- Reconnect helper returns a ReconnectOutcome enum (Continue/Shutdown/
Exhausted) instead of a bare bool.
- qconnect_service.rs logs the new events and emits a diagnostic when
the cap is exceeded so the higher layer can react (#358-fix-3 will
surface it in the UI).
- Unit tests cover the cap behavior and the unbounded fallback.
Refs #358
cc
Root cause: inner_payload from CloudPayload.payload IS a QConnectBatch
(QConnectMessages) with repeated QConnectMessage entries in field 3.
The QCloudInnerEnvelope struct incorrectly treated field 3 as opaque
bytes, keeping only the last repeated entry and losing all messages.
Additionally, QConnectMessages.messages_time was declared as uint64
(wire type 0/varint) but the server sends fixed64 (wire type 1),
causing a wire type mismatch that would fail decoding.
Changes:
- Remove QCloudInnerEnvelope struct entirely
- Pass inner_payload directly to decode_queue_server_events/decode_renderer_server_commands
- Fix messages_time from uint64 to fixed64 to match server wire format
Verified against qonductor proto definitions (QConnectBatch) used in
working POC v1 and v2 implementations.
Root cause: server wraps QConnectMessage inside an inner envelope with
fields 1 (correlation_id), 2 (sequence), 3 (actual message bytes).
We were passing the envelope directly to QConnectMessage::decode(),
which silently skipped the unknown wrapper fields and found nothing.
Also restructure bootstrap: controller join first (works without
session_uuid), renderer join deferred until SESSION_STATE (type 81)
arrives with the session_uuid the server requires.