Fix DAC badge showing 'Default' instead of actual device

The badge was always showing 'Default' regardless of the selected device because
thread_state.set_current_device() was only being called in the legacy CPAL path,
not in the backend system path (PipeWire DAC, ALSA Direct).

Root cause:
- Lines 801-805: Backend system creates stream but never sets current_device
- Lines 847, 883: Only legacy CPAL path was setting device name from CPAL device.name()
- UI badge calls get_audio_output_status() which returns player.state.current_device()
- current_device was None/outdated when using backend system

Fix:
- After successful stream creation (line 897), read output_device from settings
- Set thread_state.current_device with the device name from settings
- Fallback to 'Default' string if output_device is None
- Now badge shows: 'hw:4,0', 'DacMagic Plus Analog Stereo', etc.

Testing:
- ALSA Direct: Should show 'hw:4,0' or configured device
- PipeWire DAC: Should show 'DacMagic Plus Analog Stereo' or selected sink
- System Default: Should show 'Default'
This commit is contained in:
vicrodh committed 2026-01-19 11:29:11 -06:00
1 parent f88cee7674
commit 97c9473790
1 file changed
+13 -1
+13 -1
View File
@@ -899,7 +899,19 @@ impl Player {
*current_sample_rate = Some(sample_rate);
*current_channels = Some(channels);
thread_state.set_stream_error(false);
log::info!("✅ Audio stream ready at {}Hz", sample_rate);
// Set current device name from settings (for backend system)
if let Some(settings) = thread_settings.lock().ok() {
if let Some(ref device_name) = settings.output_device {
thread_state.set_current_device(Some(device_name.clone()));
log::info!("✅ Audio stream ready at {}Hz on device: {}", sample_rate, device_name);
} else {
thread_state.set_current_device(Some("Default".to_string()));
log::info!("✅ Audio stream ready at {}Hz on default device", sample_rate);
}
} else {
log::info!("✅ Audio stream ready at {}Hz", sample_rate);
}
// Small delay to ensure stream is fully initialized before decoder starts
// This prevents sync gaps when changing sample rates